| 266GST – 266GST Gauge pressure transmitter, base accuracy 0.04 % |
|
|
|
| Sensor Span Limits / Overpressure |
U |
30 and 3000 kPa (0.3 and 30 bar, 4.35 and 435 psi) / 6 MPa (60 bar, 870 psi) |
| Diaphragm Material / Fill Fluid |
K |
Hastelloy C-276 / Silicone oil |
| Process Connection Material / Type |
P |
AISI 316L SST (1.4404) / DIN EN 837-1 G 1/2 B |
| Gasket Material |
N |
None |
| Housing Material / Electrical Connection |
B |
Aluminium alloy (Barrel type) / M20 x 1.5 |
| Output |
1 |
HART digital communication and 4 … 20 mA |
| Explosion Protection Certification |
EW |
Combined ATEX – Intrinsic Safety, Flameproof and Type „N“ |
| Integral LCD |
L1 |
With integral LCD display |
| Certificates |
C1 |
Inspection certificate 3.1 acc. EN 10204 of calibration |